Picture of Mannok Polyiso 8 x 4 100mm sheet

Mannok Polyiso 8 x 4 100mm sheet

PY18055
Key Features
- Thermal Conductivity (λ) 0.022w/mk. Low thermal conductivity, minimising the thickness required to achieve the design U-value.
- High compressive strength - Compressive strength>150kPa
- Certified under BBA certificate number 07/4444
- Reaction to Fire: Euro Class E EN 13501-1 insulation
€52.75 inc VAT
Picture of Mannok Polyiso 8 x 4 125mm sheet

Mannok Polyiso 8 x 4 125mm sheet

PY18086
Key Features
- Thermal Conductivity (λ) 0.022w/mk. Low thermal conductivity, minimising the thickness required to achieve the design U-value.
- High compressive strength - Compressive strength>150kPa
- Certified under BBA certificate number 07/4444
- Reaction to Fire: Euro Class E EN 13501-1
€90.25 inc VAT
Picture of Mannok Polyiso 8 x 4 150mm sheet

Mannok Polyiso 8 x 4 150mm sheet

PY18087
Key Features
- Thermal Conductivity (λ) 0.022w/mk. Low thermal conductivity, minimising the thickness required to achieve the design U-value.
- High compressive strength - Compressive strength>150kPa
- Certified under BBA certificate number 07/4444
- Reaction to Fire: Euro Class E EN 13501-1
€81.95 inc VAT
Picture of Mannok Polyiso 8 x 4 25mm sheet

Mannok Polyiso 8 x 4 25mm sheet

PY18044
Key Features
- Thermal Conductivity (λ) 0.022w/mk. Low thermal conductivity, minimising the thickness required to achieve the design U-value.
- High compressive strength - Compressive strength>150kPa
- Certified under BBA certificate number 07/4444
- Reaction to Fire: Euro Class E EN 13501-1
€31.50 inc VAT
Picture of Mannok Polyiso 8 x 4 50mm sheet

Mannok Polyiso 8 x 4 50mm sheet

PY18049
Key Features
- Thermal Conductivity (λ) 0.022w/mk. Low thermal conductivity, minimising the thickness required to achieve the design U-value.
- High compressive strength - Compressive strength>150kPa
- Certified under BBA certificate number 07/4444
- Reaction to Fire: Euro Class E EN 13501-1
€35.01 inc VAT
Picture of Mannok Polyiso 8 x 4 60mm sheet

Mannok Polyiso 8 x 4 60mm sheet

PY18050
Key Features
- Thermal Conductivity (λ) 0.022w/mk. Low thermal conductivity, minimising the thickness required to achieve the design U-value.
- High compressive strength - Compressive strength>150kPa
- Certified under BBA certificate number 07/4444
- Reaction to Fire: Euro Class E EN 13501-1
€41.25 inc VAT
Picture of Mannok Polyiso 8 x 4 70mm sheet

Mannok Polyiso 8 x 4 70mm sheet

PY18051
Key Features
- Thermal Conductivity (λ) 0.022w/mk. Low thermal conductivity, minimising the thickness required to achieve the design U-value.
- High compressive strength - Compressive strength>150kPa
- Certified under BBA certificate number 07/4444
- Reaction to Fire: Euro Class E EN 13501-1
€43.00 inc VAT
Picture of Mannok Polyiso 8 x 4 80mm sheet Insulation

Mannok Polyiso 8 x 4 80mm sheet Insulation

PY18053
Key Features
- Thermal Conductivity (λ) 0.022w/mk. Low thermal conductivity, minimising the thickness required to achieve the design U-value.
- High compressive strength - Compressive strength>150kPa
- Certified under BBA certificate number 07/4444
- Reaction to Fire: Euro Class E Insulation EN 13501-1
€57.49 inc VAT
Picture of Mannok Thermal Liner 8 x 4 102mm

Mannok Thermal Liner 8 x 4 102mm

PYR18054
Key Features
- Mannok Therm Laminate-Foil - Foil backed Insulation (both sides), laminated to Plasterboard
- A high performance, fibre free insulated board, suitable for dry-lining walls. It has a low emissivity composite foil facing on the inner side and plasterboard on the outer side.
- The low emissivity foil facing increases the thermal resistance of an unvented cavity adjacent to the board improving the overall thermal performance of the element.
- Reaction to Fire: Euro Class B s1,d0 - EN 13501-1/ EN 13950-1
€110.50 inc VAT
Picture of Mannok Thermal Liner 8 x 4 29mm

Mannok Thermal Liner 8 x 4 29mm

PYF19027
Key Features
- Mannok Therm Laminate-Kraft / MLK PIR insulation is ideally suited to be used under rafters to reduce the overall heat loss through the roof and eliminate thermal bridging through the rafters.
- With the additional benefit of its paper facer, Mannok Therm Laminate-Kraft / MLK PIR insulation is also suitable for use in dry-lining applications fixed in place using dot-and-dab adhesive or mechanical fixings.
- Certified under BBA certificate number 07/4444 and IAB certificate number 05/0223
- Zero ozone depletion potential (zero ODP) and low global warming potential (GWP)
€56.75 inc VAT
Picture of Mannok Thermal Liner 8 x 4 38mm

Mannok Thermal Liner 8 x 4 38mm

PYF19053
Key Features
- Mannok Therm Laminate-Kraft / MLK PIR insulation is ideally suited to be used under rafters to reduce the overall heat loss through the roof and eliminate thermal bridging through the rafters.
- With the additional benefit of its paper facer, Mannok Therm Laminate-Kraft / MLK PIR insulation is also suitable for use in dry-lining applications fixed in place using dot-and-dab adhesive or mechanical fixings.
- Certified under BBA certificate number 07/4444 and IAB certificate number 05/0223
- Zero ozone depletion potential (zero ODP) and low global warming potential (GWP)
€44.94 inc VAT
Picture of Mannok Thermal Liner 8 x 4 50mm

Mannok Thermal Liner 8 x 4 50mm

PYF19054
Key Features
- Mannok Therm Laminate-Kraft / MLK PIR insulation is ideally suited to be used under rafters to reduce the overall heat loss through the roof and eliminate thermal bridging through the rafters.
- With the additional benefit of its paper facer, Mannok Therm Laminate-Kraft / MLK PIR insulation is also suitable for use in dry-lining applications fixed in place using dot-and-dab adhesive or mechanical fixings.
- Certified under BBA certificate number 07/4444 and IAB certificate number 05/0223
- Zero ozone depletion potential (zero ODP) and low global warming potential (GWP)
€48.74 inc VAT
Picture of Mannok Thermal Liner 8 x 4 63mm

Mannok Thermal Liner 8 x 4 63mm

PYF19059
Key Features
- Mannok Therm Laminate-Kraft / MLK PIR insulation is ideally suited to be used under rafters to reduce the overall heat loss through the roof and eliminate thermal bridging through the rafters.
- With the additional benefit of its paper facer, Mannok Therm Laminate-Kraft / MLK PIR insulation is also suitable for use in dry-lining applications fixed in place using dot-and-dab adhesive or mechanical fixings.
- Certified under BBA certificate number 07/4444 and IAB certificate number 05/0223
- Zero ozone depletion potential (zero ODP) and low global warming potential (GWP)
€55.76 inc VAT
Picture of Mannok Thermal Liner 8 x 4 73mm

Mannok Thermal Liner 8 x 4 73mm

PYF19061
Key Features
- Mannok Therm Laminate-Kraft / MLK PIR insulation is ideally suited to be used under rafters to reduce the overall heat loss through the roof and eliminate thermal bridging through the rafters.
- With the additional benefit of its paper facer, Mannok Therm Laminate-Kraft / MLK PIR insulation is also suitable for use in dry-lining applications fixed in place using dot-and-dab adhesive or mechanical fixings.
- Certified under BBA certificate number 07/4444 and IAB certificate number 05/0223
- Zero ozone depletion potential (zero ODP) and low global warming potential (GWP)
€65.76 inc VAT
Picture of Mannok Thermal Liner 8 x 4 82mm

Mannok Thermal Liner 8 x 4 82mm

PYF19064
Key Features
- Mannok Therm Laminate-Kraft / MLK PIR insulation is ideally suited to be used under rafters to reduce the overall heat loss through the roof and eliminate thermal bridging through the rafters.
- With the additional benefit of its paper facer, Mannok Therm Laminate-Kraft / MLK PIR insulation is also suitable for use in dry-lining applications fixed in place using dot-and-dab adhesive or mechanical fixings.
- Certified under BBA certificate number 07/4444 and IAB certificate number 05/0223
- Zero ozone depletion potential (zero ODP) and low global warming potential (GWP)
€89.25 inc VAT
Picture of Mannok Thermal Liner 8 x 4 92mm

Mannok Thermal Liner 8 x 4 92mm

PYF19065
Key Features
- Mannok Therm Laminate-Kraft / MLK PIR insulation is ideally suited to be used under rafters to reduce the overall heat loss through the roof and eliminate thermal bridging through the rafters.
- With the additional benefit of its paper facer, Mannok Therm Laminate-Kraft / MLK PIR insulation is also suitable for use in dry-lining applications fixed in place using dot-and-dab adhesive or mechanical fixings.
- Certified under BBA certificate number 07/4444 and IAB certificate number 05/0223
- Zero ozone depletion potential (zero ODP) and low global warming potential (GWP)
€102.25 inc VAT